20,993 research outputs found
Nuclear Magnetic Resonance in Low-Symmetry Superconductors
We consider the nuclear spin-lattice relaxation rate, in
superconductors with accidental nodes. We show that a Hebel-Slichter-like peak
occurs even in the absence of an isotropic component of the superconducting
gap. The logarithmic divergence found in clean, non-interacting models is
controlled by both disorder and electron-electron interactions. However, for
reasonable parameters, neither of these effects removes the peak altogether.Comment: 10 pages, 5 figure
Space infrared telescope pointing control system. Infrared telescope tracking in the presence of target motion
The use of charge-coupled-devices, or CCD's, has been documented by a number of sources as an effective means of providing a measurement of spacecraft attitude with respect to the stars. A method exists of defocussing and interpolation of the resulting shape of a star image over a small subsection of a large CCD array. This yields an increase in the accuracy of the device by better than an order of magnitude over the case when the star image is focussed upon a single CCD pixel. This research examines the effect that image motion has upon the overall precision of this star sensor when applied to an orbiting infrared observatory. While CCD's collect energy within the visible spectrum of light, the targets of scientific interest may well have no appreciable visible emissions. Image motion has the effect of smearing the image of the star in the direction of motion during a particular sampling interval. The presence of image motion is incorporated into a Kalman filter for the system, and it is shown that the addition of a gyro command term is adequate to compensate for the effect of image motion in the measurement. The updated gyro model is included in this analysis, but has natural frequencies faster than the projected star tracker sample rate for dim stars. The system state equations are reduced by modelling gyro drift as a white noise process. There exists a tradeoff in selected star tracker sample time between the CCD, which has improved noise characteristics as sample time increases, and the gyro, which will potentially drift further between long attitude updates. A sample time which minimizes pointing estimation error exists for the random drift gyro model as well as for a random walk gyro model
A phenomenological model of the superconducting state of the Bechgaard salts
We present a group theoretical analysis of the superconducting state of the
Bechgaard salts, e.g., (TMTSF)_2PF_6 or (TMTSF)_2ClO_6. We show that there are
eight symmetry distinct superconducting states. Of these only the (fully
gapped, even frequency, p-wave, triplet) 'polar state' is consistent with the
full range of the experiments on the Bechgaard salts. The gap of the polar
state is d(k) (psi_uk,0,0), where psi_uk may be any odd parity function that is
translationally invariant.Comment: 4 pages, no figure
Preliminary guide to the identification of the early life history stages of Gerreid fishes of the Western Central Atlantic
The family Gerreidae contains four genera and 13 species that occur in the western central North Atlantic. Adult gerreids are small to medium size fishes that are abundant in coastal waters, bays, and estuaries in tropical and warm temperate regions and sometimes occur in freshwaters. They are generally associate~ with grassy or open bottoms, but not with reefs. Gerreids are silvery fishes, with deeply forked tails, and extremely protrusible mouth that points
downward when protracted. They apparently feed on bottom-dwelling organisms and at least one species (Eucinostomus gula) shows a distinct transition, during the juvenile period, from a planktivore (exclusively copepods) to a carnivore that includes a diet of almost solely
polychaetes (Carr & Adams, 1973; Robins and Ray, 1987; Murdy et al., 1997). (PDF contains 10 pages
Advanced combined iodine dispenser and detector
A total weight of 1.23 kg (2.7 lb), a total volume of 1213 cu m (74 cu in), and an average power consumption of 5.5W was achieved in the advanced combined iodine dispenser/detector by integrating the detector with the iodine source, arranging all iodinator components within a compact package and lowering the parasitic power to the detector and electronics circuits. These achievements surpassed the design goals of 1.36 kg (3.0 lb), 1671 cu m (102 cu in) and 8W. The reliability and maintainability were improved by reducing the detector lamp power, using an interchangeable lamp concept, making the electronic circuit boards easily accessible, providing redundant water seals and improving the accessibility to the iodine accumulator for refilling. The system was designed to iodinate (to 5 ppm iodine) the fuel cell water generated during 27 seven-day orbiter missions (equivalent to 18,500 kg (40,700 lb) of water) before the unit must be recharged with iodine crystals
Triple redundant hydrogen sensor with in situ calibration
To meet sensing and calibration needs, an in situ calibration technique was developed. It is based on electrolytic generation of a hydrogen/air atmosphere within a hydrogen sensor. The hydrogen is generated from water vapor in the air, and being electrical in nature, the in situ calibration can be performed completely automatically in remote locations. Triply redundant sensor elements are integrated within a single, compact housing, and digital logic provides inter-sensor comparisons to warn of and identify malfunctioning sensor elements. An evaluation of this concept is presented
HIGH- AND LOW-ARCHED ATHLETES EXHIBIT SIMILAR STIFFNESS VALUES WITHIN THE LOWER EXTREMITY
Abnormal foot function has been associated with an increased propensity of injury (Kaufman et al., 1999). Both high- (HA) and low-arched (LA) athletes suffer a greater incidence of injury (Kaufman et al., 1999). Previous research has shown that HA compared to LA runners exhibit greater lower extremity stiffness and greater stiffness within the lower extremity joints (Williams et al., 2004). The purpose of the current study was to examine lower extremity stiffness as well as hip, knee and ankle joint stiffness in HA and LA athletes. It was hypothesized that the HA athletes would have greater stiffness values than the LA athletes within the lower extremity
- …